Stability Chamber
Thermolab Scientific Chambers are perfectly designed for the high requirements of stability studies and climatic tests. With Stability Chambers specifically developed to meet FDA/ICH stability requirements generating exceptional control and uniformity of both temperature and humidity.
Thermolab Stability Chambers feature various safety feature, audio visual alarms, 21 CFR part 11 software and a vast range of options and is the most preferred choice for stability studies. Every Thermolab Scientific Chamber repeatedly produces required conditions, structural integrity that keeps the chamber working properly through years of demanding test cycles and measuring equipment’s that precisely records all test data.
- Double walled modular structure with 3” thick PUF insulation
- Inside Stainless Steel and Outside Mild Steel Powder Coated OR Stainless Steel
- Interior illumination
- Inside full length observation glass door with secure gasket
- Handle and hinges for positive sealing with lock and key arrangement
- Heavy-duty door hinges and latches to maintain a secure and uniform seal
- Racks & trays – Stainless steel with adjustable height
- 65 mm Port Hole with rubber seal to insert sensors for validation purpose
- Interior illumination for working area
- U shaped S.S. Nichrome wire air heaters
- Humidity system with evaporation tray and reservoir tank with water level arrangement
- Compressor with CFC Free R 134 A / R 404 (Eco Friendly) refrigerant having state of art by-pass system for continuous run of compressor
- PLC based control system with 7” colour touchscreen HMI.
- Safety controller sensor to cut off the supply in case of overshoot and undershoot of Temperature giving audio visual alarm
- Web based online monitoring
- Complete with IQ, OQ, PQ, Documents, Operations and Maintenance manuals
- Works on 23V AC single phase 50Hz
- Complete safety and alarm system
- 21 CFR Part 11 Compliance Window based communication software for data management
- Stand by refrigeration system & Stand by humidity system (Except for 90 Ltrs.)
- Scanner 4 point temperature and 4 point humidity scanner complete with sensors and printer interface and data storage facility.
- Mobile Alert system
- Door Access Security System
- Security Alarm System
- Standard Model(S) : Inside S.S. 304 & outside mild steel powder coated
- GMP Model(G) : Inside S.S. 304 & outside S.S. 304
- Temperature Range : 20°C to 60°C
- Temperature Accuracy : ± 0.2°C
- Temp Uniformity : ± 2°C
- Humidity Range : 40% to 95% RH
- Humidity Accuracy : ± 2% RH
- Humidity Uniformity : ± 3% RH
Model | Internal | Dimensions in cms | Max No. of Trays | |||||
---|---|---|---|---|---|---|---|---|
(s)OR(G) | Cu.Ft/Ltrs. | Internal | External | |||||
W | D | H | W | D | H | |||
TH 90 S/G | 3/900 | 45 | 40 | 50 | 60 | 82 | 104 | 3 |
TH 200/G | 8/200 | 60 | 63 | 60 | 75 | 106.5 | 117 | 4 |
TH 325/G | 12/325 | 60 | 60 | 90 | 75 | 106.5 | 147 | 6 |
TH 400 S/G | 16/400 | 60 | 63 | 106 | 75 | 106.5 | 163 | 7 |
TH 600 S/G | 22/600 | 80 | 80 | 95 | 95 | 126.5 | 154 | 6 |
TH 800 S/G | 28/800 | 80 | 80 | 125 | 95 | 126.5 | 187 | 9 |
TH 1000 S/G | 32/1000 | 80 | 8 | 157 | 95 | 126.5 | 219 | 11 |
Temperature & Humidity Conditions as per ICH Guidelines:
25°C & 60%
30°C & 65%
30°C & 75%
40°C & 75%
Low RH chambers are also available on request for below
conditions:
25°C & 40% RH
40°C & 25% RH
30°C & 35% RH